Coaxial cable loss calculator
Work out how much signal a coaxial cable run loses. Enter the attenuation figure from the datasheet of your own cable, the frequency that figure is given for, your operating frequency and the cable length.
Cable loss
This calculator has no built-in cable table: attenuation differs between manufacturers and constructions of the same cable type, so the figure must come from the datasheet of the cable you use. When the operating frequency differs from the datasheet frequency the result is an estimate (see below).
Formulas used
α(f) ≈ α(f0) · √(f / f0)Lcable(dB) = α(f) · lengthLtotal(dB) = Lcable + LconnectorsPout(dBm) = Pin(dBm) − LtotalPower delivered (%) = 100 · 10 ^ (−Ltotal / 10)
α(f0) is the datasheet attenuation at frequency f0. The square-root rule assumes that conductor (skin-effect) loss dominates. Dielectric loss grows in proportion to frequency, so at high frequencies the rule gives a lower figure than the real cable; it is exact only when f = f0. Unit conversions: 100 ft = 30.48 m. The figures apply to a matched 50 Ω or 75 Ω line at room temperature; mismatch, tight bends and heat add loss.
More calculators: dBm, watt and EIRP calculator · Free-space path loss and link budget calculator · All RF calculators